Mostrar el registro sencillo del ítem

dc.contributor.advisorSantayana Vela, Toribio Sebastián
dc.contributor.authorAsencios Astorayme, Henry Joel
dc.date.accessioned2016-12-05T13:17:52Z
dc.date.available2016-12-05T13:17:52Z
dc.date.issued2016
dc.identifier.otherP10.A8455-T BAN UNALM
dc.identifier.urihttps://hdl.handle.net/20.500.12996/1957
dc.descriptionUniversidad Nacional Agraria La Molina. Facultad de Ingeniería Agrícola. Departamento Académico de Recursos Hídricoses_PE
dc.description.abstractLa precipitación es una de las principales variables que dinamizan el ciclo hidrológico. En el Perú, la red de estaciones pluviométricas que monitorea el SENAMHI presenta una baja densidad o, en algunos casos, no existe. En contraste, debido al avance tecnológico se cuenta con series de precipitación estimada por satélite que presentan una aceptable cobertura espacial y están disponibles en tiempo real. Esta información que podría ser utilizada en la simulación de caudales a nivel de cuenca, necesita de una evaluación de la precisión con la que ha sido obtenida. Por ello, la presente investigación tiene como objetivo principal evaluar el rendimiento de tres productos de precipitación estimada por satélite denominados TRMM-3B42RT, CMORPH y PERSIANN con y sin sesgo corregido en la simulación de caudales de las principales unidades hidrográficas de la cuenca del río Rímac. Para corregir el sesgo de las series de precipitación, se ha utilizado dos métodos denominados Factor de Error de Precipitación y Mapeo Cuantil. Asimismo, se ha utilizado el modelo HYMOD para realizar la simulación del proceso de precipitación-escorrentía. El algoritmo DREAM ha sido utilizado para realizar la calibración del modelo hidrológico, en donde se ha configurado 10 secuencias paralelas y 1000 simulaciones o muestras en el proceso de obtención de la magnitud de los parámetros del modelo HYMOD. Los resultados muestran que, la precipitación estimada por satélite subestima largamente la serie de lluvia observada. Los caudales simulados utilizando la información de precipitación estimada por satélite sugieren que éstos no son útiles en su forma en que están disponibles. Se ha encontrado que utilizando los métodos de corrección de sesgo evaluados, ha sido posible mejorar el rendimiento de los productos de precipitación en la simulación de caudales. Específicamente, se ha obtenido mejores resultados utilizando el método Mapeo Cuantil aplicado a los productos TRMM-3B42RT y PERSIANNes_PE
dc.description.abstractRainfall is one of the main variables that mobilizes hydrological cycle. In Peru, the network of meteorological stations which is monitored by SENAMHI has low density or, in some cases, does not exist. Nevertheless, due to technological advances there is available satellite precipitation products which have acceptable spatial coverage and are accessible in real time. This information could be used in the simulation of flows at the basin level, therefore it is neccessary to carry out an assessment of the accuracy to this kind of information. Consequently, this research has as main purpose to evaluate the performance of three satellite precipitation products called TRMM-3B42RT, CMORPH and PERSIANN with and without bias correction in the streamflow simulation of Rímac River basin. In order to correct the bias of the series of precipitation, it has been used two methods well-known as Factor Error and Quantile Mapping. It also has been used HYMOD model for carrying out the simulation of rainfall-runoff process. The DREAM algorithm has been used for calibrating the hydrological model, in which was taken into consideration 10 parallel sequences and 1000 simulations or samples in the process of obtaining the magnitude of the parameters. The results show that the satellite precipitation products underestimate the observed series of rain. The simulated flows using satellite precipitation products suggest that these are not useful in their way are available. It has been found that using the applied methods has been possible to improve the performance of precipitation products in hydrologic modelling. Specifically, it have been possible to obtain better results using the Quantile Mapping method applied to the TRMM-3B42RT and PERSIANN productsen_US
dc.description.uriTesises_PE
dc.formatapplication/pdfen_US
dc.language.isospaes_PE
dc.publisherUniversidad Nacional Agraria La Molinaes_PE
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceUniversidad Nacional Agraria La Molinaes_PE
dc.sourceRepositorio institucional - UNALMes_PE
dc.subjectCuenca del río Rimaces_PE
dc.subjectSimulación de caudaleses_PE
dc.subjectPrecipitación estimada por satélitees_PE
dc.subjectCorrección del sesgoes_PE
dc.subjectCursos de aguaes_PE
dc.subjectCuencas hidrográficases_PE
dc.subjectPrecipitación atmosféricaes_PE
dc.subjectPrecipitación artificiales_PE
dc.subjectSimulaciónes_PE
dc.subjectModelos de simulaciónes_PE
dc.subjectSatéliteses_PE
dc.subjectEvaluaciónes_PE
dc.subjectMétodos estadísticoses_PE
dc.subjectPerúes_PE
dc.titleCorrección del sesgo de la precipitación estimada por satélite para la simulación de caudales en la cuenca del río Rímaces_PE
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
thesis.degree.disciplineRecursos Hídricoses_PE
thesis.degree.grantorUniversidad Nacional Agraria La Molina. Facultad de Ingeniería Agrícolaes_PE
thesis.degree.nameIngeniero Agrícolaes_PE
thesis.degree.levelTítulo Profesionales_PE


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess