dc.description.abstractFrente a la incertidumbre de que si el edificio de la Biblioteca Agrícola Nacional, ubicado dentro del campus de la Universidad Nacional Agraria La Molina, en el distrito de La Molina, resistirá eficientemente un evento sísmico importante, se plantea una evaluación sismorresistente, que se basa en el análisis de los desplazamientos laterales de la edificación producto de las fuerzas sísmicas. La edificación de concreto armado, de 4 niveles y un sótano, fue construida entre los años 1965 y 1969 con un sistema estructural aporticado con poca presencia de placas de corte, lo que hacía de esta, una estructura flexible; por esta razón, fue reforzada en el año 1989 con placas de corte en ambos sentidos en todos los niveles, cambiando el sistema estructural a dual en ambos sentidos, con base en la Norma Sísmica de 1977 -vigente en ese entonces; ver Anexo 1-. De acuerdo a la evaluación con base en la Norma de Diseño Sismorresistente E.030 de 2003 – vigente ahora; ver anexo 2- se determina que la edificación tiene una estructura irregular debido a la discontinuidad en las losas de los pisos interiores por tener abertura abruptas entre pisos inmediatos. Luego de realizar todos los cálculos se ha determinado los desplazamientos laterales mínimos y máximos con base en la Norma Sísmica de 1977 - vigente en el año que se realizó el reforzamiento estructura y aplicando el análisis estático que se especificaba en ella. Asimismo se ha determinado los desplazamientos laterales mínimos y máximos con base en la Norma de Diseño Sismorresistente E.030 de 2003, mediante análisis estático y dinámico. Por último estos tres resultados han sido comparados para satisfacer los desplazamientos máximos permisibles de una estructura de estas características, según la Norma de Diseño Sismorresistente E.030 de 2003, que viene siendo la más conservadora. De esta manera se concluyó que los desplazamientos laterales máximos de la edificación frente al sacudimiento del suelo producto de las aceleraciones que provoca un evento sísmico, no están dentro de los valores permisibles y se recomienda un estudio sismorresistente integral, para determinar un posible reparación y/o reforzamiento estructural.es_PE
dc.description.abstractFaced with the uncertainty of whether the building of the National Agricultural Library, located inside the campus of the College National Agrarian La Molina, in the district of La Molina, efficiently withstand a major seismic event, seismic evaluation, based raises in the analysis of the lateral displacements of the building product seismic forces. The reinforced concrete building, 4 levels and a basement, was built between 1965 and 1969 with a structural framed system with little presence of cutting plates, making this a flexible structure; for this reason, it was reinforced in 1989 with plates cut in both directions at all levels, changing the structural system to dual two-way, based on the seismic code 1977 -in force at the time; See Annex 1. According to the evaluation based on Seismic Design Standard E.030 2003 -in force now; see Annex 2 is determined that the building has an irregular structure due to the discontinuity in the slabs of interior floors by having immediate abrupt opening between floors. After making all the calculations we have determined the minimum and maximum lateral displacements based on the 1977 Standard seismic - force in the year that the strengthening structure is made and applying static analysis which specified therein. It has also given minimum and maximum lateral displacements based Seismic Design Standard E.030, 2003, through static and dynamic analysis. Finally these three results have been compared to satisfy the maximum allowable displacement of a structure of this kind, according to the Seismic Design Standard E.030 2003, which has been the most conservative. Thus it was concluded that the lateral displacements top of the building facing the ground shaking product accelerations caused a seismic event, are not within allowable values and a seismic comprehensive study is recommended to determine a possible repair and / or structural reinforcement.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfen_US
dc.language.isospaes_PE
dc.publisherUniversidad Nacional Agraria La Molinaes_PE
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceUniversidad Nacional Agraria La Molinaes_PE
dc.sourceRepositorio institucional - UNALMes_PE
dc.subjectNorma E.030es_PE
dc.subjectReglamento nacional de edificaciones (2003)es_PE
dc.subjectBibliotecases_PE
dc.subjectConstrucción de edificioses_PE
dc.subjectEvaluaciónes_PE
dc.subjectSismologiaes_PE
dc.subjectNormases_PE
dc.subjectReglamentacioneses_PE
dc.subjectPerúes_PE
dc.subjectBiblioteca Agrícola Nacionales_PE
dc.subjectDesplazamientos lateraleses_PE
dc.subjectSolicitaciones sísmicases_PE
dc.titleEvaluación de desplazamientos laterales por solicitaciones sísmicas del edificio de la Biblioteca Agrícola Nacional según la normativa vigentees_PE
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
thesis.degree.disciplineOrdenamiento Territorial y Construcciónes_PE
thesis.degree.grantorUniversidad Nacional Agraria La Molina. Facultad de Ingeniería Agrícolaes_PE
thesis.degree.nameIngeniero Agrícolaes_PE
thesis.degree.levelTítulo Profesionales_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess