Mostrar el registro sencillo del ítem

dc.contributor.advisorRamos Fernández, Lía
dc.contributor.authorPaz Cárdenas, Carlos Alberto
dc.date.accessioned2018-04-19T14:01:55Z
dc.date.available2018-04-19T14:01:55Z
dc.date.issued2018
dc.identifier.otherF06.P39-T BAN UNALM
dc.identifier.urihttps://hdl.handle.net/20.500.12996/3225
dc.descriptionUniversidad Nacional Agraria La Molina. Facultad de Ingeniería Agrícola. Departamento Académico de Recursos Hídricoses_PE
dc.description.abstractAlcanzar el uso eficiente del agua requiere un proceso de medición minucioso de los caudales que circulan en las diferentes etapas de conducción y distribución, cuyo resultado determina la cantidad disponible de dicho recurso, lo que a su vez brinda la oportunidad de proponer medidas eficaces en el uso del mismo. En ese sentido, frente a los múltiples resultados que se pueden obtener bajo el empleo de un modelo hidráulico aplicado en redes, se determinó que el uso de ciertos instrumentos de medición, permitió alcanzar variables hidráulicas más exactas en el seguimiento eficaz del agua. En la presente investigación se calibró un medidor de tipo ultrasónico para sistemas de abastecimiento de agua con fines de riego, convirtiéndolo en una alternativa tecnológica de medición confiable, no invasiva y de fácil instalación, alcanzando una mejora considerable en la gestión técnica y el control en la reducción de las pérdidas de agua en estos sistemas de abastecimiento. La investigación se dividió en tres etapas; la primera etapa consistió en la calibración del medidor de flujo ultrasónico mediante la implementación de un tanque de pruebas, donde se determinó que el factor de calibración del medidor es 1.09 para las condiciones específicas del proyecto y asimismo, fue necesario obtener la curva de calibración de caudal para el canal San Ramón; aquí se estableció la altura de agua necesaria que garantiza el ingreso de 280 litros/seg para el abastecimiento del Subtroncal 3. La segunda etapa consistió en realizar los cálculos hidráulicos a través de un modelo hidráulico Watercad, cuyos resultados sirvieron como base para el monitoreo de los caudales en campo utilizando el medidor de flujo ultrasónico calibrado, actividad que forma parte de la tercera etapa. Finalmente, de los resultados del monitoreo se ha constatado que el uso del medidor de flujo ultrasónico calibrado representa el caudal que circula por la red hidráulica, siendo una opción de empleo en actividades relacionadas al monitoreo y control del caudales_PE
dc.description.abstractAchieve the efficient use of water requires a meticulous measurement process of its flow rates on the different stages of a conduction and distribution system, the result of measurement determines the available quantity of this resource, which offered the opportunity to propose effective ways in the use of water, in this sense, in view of the multiple results that can be obtained under the use of a hydraulic model applied in networks, it was determined that the use of certain measuring instruments allowed to reach the most exact hydraulic variables in water monitoring. In the present research an ultrasonic flowmeter has been calibrated for water supply systems for irrigation purposes, turning it into a reliable, non-invasive and easy-to-install technological measurement alternative, achieving a considerable improvement in the management and the control of water losses in these water supply systems. The investigation was divided into three phases; The first stage consisted in the calibration of “Ultrasonic Flowmeter (UF)” through the installation of a test tank, where it was determined that the UF’s calibration factor was 1.09 for the specific project conditions, also it was necessary to obtain the flow calibration for the San Ramón water channel; Also, here the necessary water level was established, which guarantees the entry of 280 liters per second for supply of "Subtroncal 3”. The second stage consisted of performing the hydraulic calculations using a hydraulic model in Watercad, whose results were considered as a basis for the monitoring of the flow rates in the field, using the calibrated UF, this last one activity is the third stage. Finally, the results of the monitoring determine that the use of the calibrated UF represents the hydraulic network flow, which is used in activities related to the monitoring and controlen_US
dc.description.uriTesises_PE
dc.formatapplication/pdfen_US
dc.language.isospaes_PE
dc.publisherUniversidad Nacional Agraria La Molinaes_PE
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceUniversidad Nacional Agraria La Molinaes_PE
dc.sourceRepositorio institucional - UNALMes_PE
dc.subjectRiegoes_PE
dc.subjectSistemas de riegoes_PE
dc.subjectRecursos hídricoses_PE
dc.subjectMediciónes_PE
dc.subjectEcosondeoes_PE
dc.subjectEstimaciónes_PE
dc.subjectMétodos estadísticoses_PE
dc.subjectEvaluaciónes_PE
dc.subjectPerúes_PE
dc.subjectSistema hidráulicoes_PE
dc.subjectSistema de irrigación Pangoaes_PE
dc.subjectMedición de caudales_PE
dc.subjectFlujo ultrasónicoes_PE
dc.subjectRed hidráulicaes_PE
dc.titleCalibración hidráulica de la red de tuberías del sistema de irrigación Pangoa, Subtroncal 3 - Departamento de Junínes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
thesis.degree.disciplineRecursos Hídricoses_PE
thesis.degree.grantorUniversidad Nacional Agraria La Molina. Facultad de Ingeniería Agrícolaes_PE
thesis.degree.nameIngeniero Agrícolaes_PE
thesis.degree.levelTítulo Profesionales_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#4.01.01es_PE


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess