Mostrar el registro sencillo del ítem

dc.contributor.advisorCabrera Villanueva, Próspero Celestino
dc.contributor.authorGálvez Suasnabar, Josué Amador
dc.date.accessioned2022-03-10T22:00:24Z
dc.date.available2022-03-10T22:00:24Z
dc.date.issued2022
dc.identifier.urihttps://hdl.handle.net/20.500.12996/5263
dc.descriptionUniversidad Nacional Agraria La Molina. Facultad de Zootecnia. Departamento Académico de Producción Animales_PE
dc.description.abstractEl objetivo del estudio fue comparar el efecto de dos dilutores comerciales (basados en lecitina de soya Andromed® y basados en liposomas Optixcell®) sobre las variables de calidad y funcionalidad de los espermatozoides después de la descongelación evaluados mediante análisis de esperma asistido por computadora. Se analizaron un total de 40 eyaculados de cuatro toros de la raza Brown Swiss de 3 a 6 años de edad; los tratamientos fueron: T1, eyaculados diluidos en lecitina de soya; T2, eyaculados diluidos en liposomas. El análisis de la motilidad espermática se obtuvo con ayuda de un sistema computarizado de análisis seminal (CASA); para el estudio de viabilidad espermática se empleó la tinción de fluorescencia Hoeschst 33342/PI, y la evaluación de la funcionalidad de la membrana espermática se realizó a través del test de endosmosis. En la parte estadística, se verificó los supuestos de normalidad (Shapiro-Wilk) y la homogeneidad de varianzas (Test de Levene), posteriormente se realizó el análisis de varianzas (ANVA), y los datos se analizaron con el programa estadístico Statgraphics Centurion. Se determinó que no hubo diferencias estadísticas significativas (P<0,05) en los parámetros de porcentaje de motilidad total (75.20 % y 75.51 %), viabilidad (60.65 % y 60.80 %) y funcionalidad de la membrana espermática (49.05% y 51.48%) para Andromed y Optixcell, respectivamente. Se concluye que los dilutores Andromed y Optixcell presentaron valores aceptables de la calidad seminal postdescongelación, y pueden utilizarse para la criopreservación de semen de toroes_PE
dc.description.abstractThe study was conducted to compare the effect of two commercially available extenders (Andromed®-plant based and Optixcell®-liposome-based) on post‐thaw sperm quality and functionality variables evaluated using computer‐assisted sperm analysis. A total of 40 ejaculates from four Brown Swiss breed bulls from 3 to 6 years of age were analyzed; the treatments were: T1, ejaculates diluted in soy lecithin; T2, ejaculates diluted in liposomes. Sperm motility analysis was obtained with the help of a computerized semen analysis system (CASA); Hoeschst 33342 / PI fluorescence staining was used for the sperm viability study, and the evaluation of the sperm membrane functionality was performed through the endosmosis test. In the statistical part, the assumptions of normality (Shapiro-Wilk) and the homogeneity of variances (Levene's test) were verified, later the analysis of variances (ANVA) was performed, and the data were analyzed with the statistical program Statgraphics Centurion. It was determined that there were no statistically significant differences (p> 0.05) in the parameters of percentage of total motility (75.20% and 75.51%), viability (60.65% and 60.80%) and functionality of the sperm membrane (49.05% and 51.48 %) for Andromed and Optixcell, respectively. It is concluded that the dilutors Andromed and Optixcell presented acceptable values of post-thaw semen quality, and can be used for the cryopreservation of bull semenen_US
dc.formatapplication/pdfen_US
dc.language.isospaes_PE
dc.publisherUniversidad Nacional Agraria La Molinaes_PE
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subjectToroses_PE
dc.subjectSemenes_PE
dc.subjectDilutoreses_PE
dc.subjectConservación del semenes_PE
dc.subjectRefrigeraciónes_PE
dc.subjectAlmacenamiento en frioes_PE
dc.subjectInseminación artificiales_PE
dc.subjectProducción animales_PE
dc.subjectEvaluaciónes_PE
dc.subjectPerúes_PE
dc.subjectDilutores del semenes_PE
dc.titleEvaluación de dilutores a base de lecitina de soya y liposomas sobre la criopreservación de espermatozoides de toroses_PE
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
thesis.degree.disciplineZootecniaes_PE
thesis.degree.grantorUniversidad Nacional Agraria La Molina. Facultad de Zootecniaes_PE
thesis.degree.nameIngeniero Zootecnistaes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#1.06.07es_PE
renati.author.dni45667210es_PE
dc.publisher.countryPEes_PE
dc.type.versioninfo:eu-repo/semantics/publishedVersionen_US
renati.advisor.orcidhttps://orcid.org/0000-0002-1168-9902es_PE
renati.advisor.dni08465156es_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline811306es_PE
renati.jurorMellisho Salas, Edwin Alberto
renati.jurorAlvarado Malca, Armando Enrique
renati.jurorGamarra Carrillo, Segundo Gregorio


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess