Mostrar el registro sencillo del ítem

dc.contributor.advisorAscencios Templo, David Ricardo
dc.contributor.authorMarquez Calderon, Celia Stephania
dc.date.accessioned2024-02-27T21:10:00Z
dc.date.available2024-02-27T21:10:00Z
dc.date.issued2023
dc.identifier.urihttps://hdl.handle.net/20.500.12996/6294
dc.descriptionUniversidad Nacional Agraria La Molina. Facultad de Ingeniería Agrícola. Departamento Académico de Recursos Hídricoses_PE
dc.description.abstractEl manejo de un fundo agrícola demanda un alto recurso humano para el mantenimiento y operación de los cultivos y sistema de riego tecnificado. El encendido de los equipos (electrobomba y válvulas hidráulicas) es una labor constante que se realiza de forma diaria y la operación manual puede generar fallas en el sistema de riego presurizado por una mala operación, por tal razón, la automatización y telecontrol de riego tecnificado es una herramienta de gestión ideal que reduce las fallas por errores humanos, y permite umbrales de riego de 24 horas. El presente trabajo consistió en realizar la automatización y telecontrol del fundo “Rancho Chico – Andahuasi”, ubicado en el distrito de Sayán, provincia de Huaura, departamento de Lima. El área de trabajo fue 52.63 has de cultivos de palto. El fundo contó con 4 turnos de riego con 3 laterales de riego por hilera de árboles, el caudal de gotero fue 2 lt/hr espaciados a cada 0.5 metros y se evaluó el diseño hidráulico y se observó que se garantiza las presiones y caudales para cada válvula de riego. La implementación de automatización y telecontrol se realizó en 3 etapas: la primera, inicio con la selección y ubicación de las RTU, válvulas, solenoides y antenas y se desarrolló el plano de automatización. La segunda, continuó con la instalación del sistema de radiofrecuencia. Tercero, se realizó el metrado y presupuesto del sistema de automatización.es_PE
dc.description.abstractThe management of an agricultural fund requires a high human resource for the maintenance and operation of crops and the technified irrigation system. The turning on of the equipment (electropump and hydraulic valves) is a constant labor that is carried out daily, and the manual operation can generate failures in the pressurized irrigation system due to a bad operation. Therefore, the automation and remote control of technified irrigation is an ideal management tool that reduces failures due to human errors and allows for 24-hour irrigation thresholds. The present work consisted of automating and remote controlling the "Rancho Chico - Andahuasi" farm, located in the district of Sayán, Huaura province, Lima department. The work area was 52.63 hectares of avocado crops. The farm had 4 irrigation shifts with 3 irrigation laterals per row of trees, the dripper flow was 2 lt/hr spaced every 0.5 meters and the hydraulic design was evaluated, and it was observed that it guarantees the pressures and flows for each irrigation valve. The implementation of automation and remote control was carried out in 3 stages: the first started with the selection and location of the RTUs, valves, solenoids, and antennas and the automation plan was developed. The second continued with the installation of the radio frequency system. Thirdly, the measurement and budget for the automation system was carried out.es_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Nacional Agraria La Molinaes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/es_PE
dc.subjectAutomatizaciónes_PE
dc.titleDiseño e instalación de la automatización vía radiofrecuencia del sistema de riego por goteo, fundo Rancho Chico – Andahuasies_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.disciplineIngeniería Agrícolaes_PE
thesis.degree.grantorUniversidad Nacional Agraria La Molina. Facultad de Ingeniería Agrícolaes_PE
thesis.degree.nameIngeniero Agrícolaes_PE
dc.subject.ocdependientees_PE
renati.author.dni48137882es_PE
dc.publisher.countryPEes_PE
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_PE
renati.advisor.orcidhttps://orcid.org/0000-0001-6161-5162es_PE
renati.advisor.dni07935653es_PE
renati.typehttps://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesionales_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline811096es_PE
renati.jurorMontalvo Arquiñigo, Néstor
renati.jurorSánchez Delgado, Miguel Ángel
renati.jurorGoicochea Ríos, Javier Antonio


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess