Mostrar el registro sencillo del ítem
Evaluación de la exposición al ruido ocupacional en la planta de reciclaje de la municipalidad de La Molina
dc.contributor.advisor | Sotomayor Melo, Diego Alejandro | |
dc.contributor.author | Argüero Flores, Carlos Gabriel | |
dc.date.accessioned | 2024-03-05T01:06:17Z | |
dc.date.available | 2024-03-05T01:06:17Z | |
dc.date.issued | 2024 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12996/6306 | |
dc.description | Universidad Nacional Agraria La Molina. Facultad de Ciencias. Departamento Académico de Ingeniería Ambiental, Física y Meteorología | es_PE |
dc.description.abstract | Este estudio investigó la exposición al ruido ocupacional en la planta de reciclaje de la municipalidad de La Molina. El objetivo principal fue el de identificar los niveles de presión sonora equivalentes en 8 horas (LA Ex.8h) en estaciones de ruido dentro de la planta de reciclaje, donde se analizaron los posibles impactos del ruido en los trabajadores y se compararon los valores con los estándares de exhibición recomendados a nivel nacional e internacional. Las mediciones de los niveles de ruido en las estaciones de trabajo arrojaron los siguientes resultados: PR-1 (86,9 dB(A)), PR-2 (76,4 dB(A)), PR-3 (72,2 dB(A)), PR-4 (69,3 dB(A)), PR-5 (67,1 dB(A)) y PR-6 (82,2 dB(A)). En complemento, una encuesta realizada mostró que el ruido ocupacional en las estaciones de trabajo está causando molestias significativas a una parte de la población trabajadora, según la percepción del personal de los trabajadores y la magnitud del ruido en las estaciones de ruido. Se detectó que en los niveles de ruido en la estación PR-1 exceden los valores respecto a la R.M. No 375-2008-TR “Norma Básica de Ergonomía y de Procedimiento de Evaluación de Riesgo Disergonómico”, con una dosis diaria de 155,7% ya que, en la base de la faja transportadora se genera constantemente el impacto entre materiales de vidrio. Para abordar esta situación, se analizó el uso de dispositivos de atenuación convencional, como tapones auditivos. La implementación de estos tapones permitiría reducir el nivel de presión sonora equivalentes en 8 horas (LA Ex.8h) en la estación PR-1 a 75,9 dB(A) y disminuir la dosis de ruido diario a 12,3%. En conclusión, este estudio resalta la urgencia de tomar medidas para controlar el ruido ocupacional en la planta de reciclaje de La Molina. Se recomienda implementar dispositivos de atenuación y establecer medidas preventivas, como controles administrativos y de ingeniería, para proteger la salud auditiva y el bienestar de los trabajadores. Por lo tanto, el uso de tapones auditivos es esencial para mejorar el ambiente laboral y garantizar condiciones de trabajo seguras y saludables en la planta de reciclaje. | es_PE |
dc.description.abstract | This study investigated occupational noise exposure at the recycling plant of the municipality of La Molina. The main objective is to identify the equivalent sound pressure levels in 8 hours (LA Ex.8h) in these noise stations, where the possible impacts of noise on workers were analyzed and the values were compared with the recommended exhibition standards at the national and international level. The measurements of the noise levels in the work stations yielded the following results: PR-1 (86.9 dB(A)), PR-2 (76.4 dB(A)), PR-3 (72.2 dB(A)), PR-4 (69.3 dB(A)), PR-5 (67.1 dB(A)), and PR-6 (82.2 dB(A)). In addition, a survey carried out showed that occupational noise at work stations is causing significant discomfort to a portion of the working population, based on staff perception of workers and the magnitude of noise at noise stations. It was detected that at station PR 1 it exceeded the maximum permissible limit in national and international standards, with a daily dose of 155.7%. To address this situation, the use of conventional attenuation devices, such as earplugs, was explored. The implementation of these plugs would reduce the equivalent sound pressure level in 8 hours (LA Ex.8h) at the PR-1 station to 75.9 dB(A) and reduce the daily noise dose to 12.3%. In conclusion, this study highlights the urgency of taking measures to control occupational noise at the La Molina recycling plant. It is recommended to implement attenuation devices and establish preventive measures, such as administrative and engineering controls, to protect the hearing health and well-being of workers. Therefore, the use of earplugs is essential to improve the work environment and ensure safe and healthy working conditions in the recycling plant. | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Nacional Agraria La Molina | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | es_PE |
dc.subject | Trabajadores | es_PE |
dc.subject | Municipalidad | es_PE |
dc.subject | Tratamiento de desperdicios | es_PE |
dc.subject | Ruido | es_PE |
dc.subject | Reciclaje de desperdicios | es_PE |
dc.subject | Contaminación acústica | es_PE |
dc.subject | Evaluación | es_PE |
dc.title | Evaluación de la exposición al ruido ocupacional en la planta de reciclaje de la municipalidad de La Molina | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.discipline | Ingeniería Ambiental | es_PE |
thesis.degree.grantor | Universidad Nacional Agraria La Molina. Facultad de Ciencias | es_PE |
thesis.degree.name | Ingeniero Ambiental | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.07.01 | es_PE |
renati.author.dni | 70493868 | es_PE |
dc.publisher.country | PE | es_PE |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_PE |
renati.advisor.orcid | https://orcid.org/0000-0003-0534-5625 | es_PE |
renati.advisor.dni | 41798242 | es_PE |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es_PE |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |
renati.discipline | 521066 | es_PE |
renati.juror | Quevedo Beltrán, Miguel Angel | |
renati.juror | Pesantes Rojas, Juan Manuel | |
renati.juror | Heidinger Abadia, Haline |